Hello - new to the forum here! I have a slight dilemma- hanging camera's (or light fixtures for that matter) off of Conduit T's has never been something anyone has ever questioned in my experience. We are using 1 1/2" rigid conduit, with a threaded T - a short nipple of 1 1/2" and the threaded hub of the camera housing screwed right in. No AHJ has ever even looked twice...but now I have a Project Manager who wants some sort of data on the amount of weight a T condolet can support. I've been thru every brand's website, can't find anything printed. Any ideas??

thanks
boo

Boo87 is offline   Reply With Quote
Join Contractor Talk

Join the #1 Electrician Forum Today - It's Totally Free!

ElectricianTalk.com - Are you a Professional Electrical Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for electricians to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that ElectricianTalk.com is a great community to join. Best of all it's totally free!

Join ElectricianTalk.com - Click Here JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ElectricianTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
Old 04-30-2012, 02:02 PM   #2
Heavily Armed Member
 
HARRY304E's Avatar
 
Join Date: Sep 2010
Location: Fascistchusetts
Posts: 29,434
Default

Quote:
Originally Posted by Boo87 View Post
Hello - new to the forum here! I have a slight dilemma- hanging camera's (or light fixtures for that matter) off of Conduit T's has never been something anyone has ever questioned in my experience. We are using 1 1/2" rigid conduit, with a threaded T - a short nipple of 1 1/2" and the threaded hub of the camera housing screwed right in. No AHJ has ever even looked twice...but now I have a Project Manager who wants some sort of data on the amount of weight a T condolet can support. I've been thru every brand's website, can't find anything printed. Any ideas??

thanks
boo
Tell him you could hang an 18 wheeler off of that set up.


Welcome to the forum.

HARRY304E is online now   Reply With Quote
Old 04-30-2012, 02:28 PM   #3
Junior Member
 
Join Date: Apr 2012
Location: Kansas City, Mo
Posts: 2
Default

I could hang HIM from the T, but the weedy git would still want engineer's specs to back it up.
Boo87 is offline   Reply With Quote
Old 04-30-2012, 03:18 PM   #4
976-EVIL
 
mcclary's electrical's Avatar
 
Join Date: Feb 2009
Location: State of Euphoria
Posts: 13,408
Default

Quote:
Originally Posted by HARRY304E

Tell him you could hang an 18 wheeler off of that set up.

Welcome to the forum.
He wants data, not an opinion.

I doubt veryy seriously he will find what he's looking for, since they are not listed for that purpose.
mcclary's electrical is offline   Reply With Quote
Old 04-30-2012, 03:22 PM   #5
Senior Member
 
360max's Avatar
 
Join Date: Jun 2011
Location: NY
Posts: 3,828
Default

Quote:
Originally Posted by mcclary's electrical View Post
He wants data, not an opinion.

I doubt veryy seriously he will find what he's looking for, since they are not listed for that purpose.


that's the engineers intent
360max is online now   Reply With Quote
Old 04-30-2012, 03:46 PM   #6
Heavily Armed Member
 
HARRY304E's Avatar
 
Join Date: Sep 2010
Location: Fascistchusetts
Posts: 29,434
Default

Quote:
Originally Posted by mcclary's electrical View Post
He wants data, not an opinion.

I doubt veryy seriously he will find what he's looking for, since they are not listed for that purpose.
He will not , but there many things we do that is not listed
HARRY304E is online now   Reply With Quote
Old 04-30-2012, 04:05 PM   #7
Member
 
Turtle3000's Avatar
 
Join Date: Feb 2012
Location: CO
Posts: 97
Default Listed Ehhh??

Let's face it while we have to use listed equipment, the UL is a bunch of good ole boys. I've worked maintenance electrical for two separate companies who made "UL" listed products. They only certified them once in a while, and our "UL agent" didn't really care. If UL really stood for something they would make these cheap chinese lights they send out be fully assembled during shipping, as most can be hung missing half the parts. Sorry ranting.....
__________________
__________________________
www.electricianztoolz.com
Turtle3000 is offline   Reply With Quote
Old 05-02-2012, 03:57 AM   #8
Senior Member
 
CDN EC's Avatar
 
Join Date: Jul 2011
Location: BC, CANADA
Posts: 1,426
Default

Quote:
Originally Posted by Boo87 View Post
Hello - new to the forum here! I have a slight dilemma- hanging camera's (or light fixtures for that matter) off of Conduit T's has never been something anyone has ever questioned in my experience. We are using 1 1/2" rigid conduit, with a threaded T - a short nipple of 1 1/2" and the threaded hub of the camera housing screwed right in. No AHJ has ever even looked twice...but now I have a Project Manager who wants some sort of data on the amount of weight a T condolet can support. I've been thru every brand's website, can't find anything printed. Any ideas??

thanks
boo
It's your job to provide that info? PM's usually have a lot more access to answers like that than guys on the ground do.
__________________
If you let the smoke out, you void the warranty. - NK
CDN EC is offline   Reply With Quote
Old 05-02-2012, 05:39 AM   #9
BBQ
Senior Member
 
BBQ's Avatar
 
Join Date: Nov 2010
Location: New England
Posts: 23,796
Default

Quote:
Originally Posted by Boo87 View Post
Hello - new to the forum here! I have a slight dilemma- hanging camera's (or light fixtures for that matter) off of Conduit T's has never been something anyone has ever questioned in my experience. We are using 1 1/2" rigid conduit, with a threaded T - a short nipple of 1 1/2" and the threaded hub of the camera housing screwed right in. No AHJ has ever even looked twice...but now I have a Project Manager who wants some sort of data on the amount of weight a T condolet can support. I've been thru every brand's website, can't find anything printed. Any ideas??

thanks
boo
I would start figuring out how to do it differently as it is a code violation to do it the way you have been doing it.

Last edited by BBQ; 05-02-2012 at 05:45 AM.
BBQ is online now   Reply With Quote
Old 05-02-2012, 05:47 AM   #10
BBQ
Senior Member
 
BBQ's Avatar
 
Join Date: Nov 2010
Location: New England
Posts: 23,796
Default

Quote:
Originally Posted by HARRY304E View Post
He will not , but there many things we do that is not listed
And in this case he was called on it so saying 'we always do it that way' is not going to help.
BBQ is online now   Reply With Quote
Old 05-02-2012, 11:37 PM   #11
Member
 
Join Date: Jan 2011
Location: Lufkin, TX
Posts: 40
Default

Quote:
Originally Posted by BBQ View Post
I would start figuring out how to do it differently as it is a code violation to do it the way you have been doing it.
If the conduit also contains the necessary wiring for the camera doesn't this apply? Specifically 2:

300.11(B) Raceways Used as Means of Support. Raceways
shall be used only as a means of support for other raceways,
cables, or nonelectrical equipment under any of the
following conditions:
(1) Where the raceway or means of support is identified for
the purpose
(2) Where the raceway contains power supply conductors
for electrically controlled equipment and is used to support
Class 2 circuit conductors or cables that are solely
for the purpose of connection to the equipment control
circuits
(3) Where the raceway is used to support boxes or conduit
bodies in accordance with 314.23 or to support luminaires
in accordance with 410.36(E).


*The more I re-read the less I think this code section apples.....


Last edited by GrislyZero; 05-04-2012 at 09:34 AM. Reason: Second Guessing
GrislyZero is offline   Reply With Quote
Reply

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
hanging transformers mkg General Electrical Discussion 7 11-15-2011 07:15 AM
Hanging in there RIVETER Off Topic 10 11-10-2011 07:53 PM
Hanging 900' of Lights Voltech General Electrical Discussion 13 10-28-2011 10:09 PM
Hanging Lights Conduit? petek57 NEC Code Forum 8 02-03-2011 10:43 AM
hanging a fan from a 4 sq? truelight Commercial Electrical Forum 44 05-01-2010 02:12 AM

Top of Page | View New Posts

All times are GMT -4. The time now is 09:42 PM.


Electrician Talk © 2006 - 2010 The Building Network

Search Engine Optimization by vBSEO 3.6.0 RC 2