Question 1/2" flex support

Does 1/2 flexible conduit (FMC) have to be supported with in 12" of the box if under 6'? The use of the flex is in a suspended ceiling. The flexible conduit is running from a j-box to P.A. systems, Mass. Notification & exit signs. It is not being used as fixture wipes. My understanding is if it is less than 6' it needs to be supported with in 12" of a box. And if it is over 6' it still need to be supported with in 12" of the box and every 4' 6" after that. I am on a project and I am on a project and I disagree with the Forman, he states that no support is necessary if under 6'. Again this is not a manufactured fixture whip.

K.B.Q.C. is offline   Reply With Quote
Join Contractor Talk

Join the #1 Electrician Forum Today - It's Totally Free!

ElectricianTalk.com - Are you a Professional Electrical Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for electricians to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that ElectricianTalk.com is a great community to join. Best of all it's totally free!

Join ElectricianTalk.com - Click Here JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ElectrcianTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
Old 07-22-2008, 09:16 PM   #2
Senior Member
 
Adam12's Avatar
 
Join Date: May 2008
Location: So.Cal
Posts: 287
Default

Your foreman is correct. FMC to a luminaire or electrical equipment within a accessible ceiling is permitted to be unsupported for not more than 6' from the last point where the raceway is securely fastened. 348.30 ex. #4
Adam12 is offline   Reply With Quote
Reply

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Support of conduit under 24" Iber NEC Code Forum 9 10-24-2008 06:27 AM
flex cord works for everything, right??? BP_redbear Code Violation Discussion 2 07-11-2008 10:08 PM
Power Flex VFD jhanth General Electrical Discussion 3 04-12-2008 03:34 PM
Greenlee flex bits knothole Tools, Equipment and New Products 25 01-22-2008 07:34 AM
Support from an LB? bruce73401 General Electrical Discussion 1 04-21-2007 08:31 AM

Top of Page | View New Posts

All times are GMT -4. The time now is 09:55 PM.


Electrician Talk © 2006 - 2010 The Building Network LLC

Search Engine Optimization by vBSEO 3.2.0