03-31-2009, 12:53 PM
|
#1
|
|
child please.....
Join Date: Oct 2008
Location: Hack City, USA aka New Orleans
Posts: 2,955
|
More Hack Pics
met with the inspector today, he came up with a list of about 25 violations...i'm going to have to re-wire the house...this lday pais the contractor over 13,000 dollars for this work...

no nipple in back of panel

no bonding screw

notice anything strange about this "feeder"?...

yeah thats the "feeder"...looks like they skinned some 4/0 aluminum se and ran they from the disconnect-no ground wire either
|
|
|
Join the #1 Electrician Forum Today - It's Totally Free!
ElectricianTalk.com - Are you a Professional Electrical Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for electricians to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that ElectricianTalk.com is a great community to join. Best of all it's totally free!
Join ElectricianTalk.com - Click Here

|
Warning: The topics covered on this site include activities in which there exists the potential for serious injury
or death. ElectrcianTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
03-31-2009, 12:55 PM
|
#2
|
|
child please.....
Join Date: Oct 2008
Location: Hack City, USA aka New Orleans
Posts: 2,955
|
excuse the spelling...i'm still recovering from seeing this house
|
|
|
03-31-2009, 01:42 PM
|
#3
|
|
Senior Member
Join Date: Mar 2007
Location: Leesburg VA
Posts: 6,508
|
I think you are just a nit picker
|
|
|
03-31-2009, 02:02 PM
|
#4
|
|
child please.....
Join Date: Oct 2008
Location: Hack City, USA aka New Orleans
Posts: 2,955
|
ya think?
|
|
|
03-31-2009, 02:11 PM
|
#5
|
|
Senior Member
Join Date: Mar 2008
Location: Toronto, Canada
Posts: 666
|
Are those the feeders laying loose in the attic?!?!?!?!
|
|
|
03-31-2009, 02:28 PM
|
#6
|
|
Seen your member
Join Date: Sep 2007
Location: Cornpatch USA
Posts: 9,954
|
__________________
This message is hidden because Forgery, JackBoot, LawnGuyLandSparky, milehiwire and user 5941 are on your ignore list.
|
|
|
03-31-2009, 02:29 PM
|
#7
|
|
That Guy
Join Date: Jan 2009
Location: NJ
Posts: 1,184
|
Wow.........so is this contractor going to jail? Only in a perfect world.....
|
|
|
03-31-2009, 03:12 PM
|
#8
|
|
child please.....
Join Date: Oct 2008
Location: Hack City, USA aka New Orleans
Posts: 2,955
|
The e.c. should go to jail along with the general contractor...i'm the 3rd electrician to be on this job...i think she hired little mexico electric to build the service....this poor lady is stuck in the middle of all of this, she almost started crying when the inspector and I were explaining all of the violations to her...i feel horrible, but it needs to be fixed
|
|
|
03-31-2009, 03:59 PM
|
#9
|
|
Senior Member
Join Date: Feb 2007
Location: Kentucky
Posts: 627
|
Kinda surprised there was even a disconnect installed with how horrid the work is. Knew to install a disconnect and forgot all about the ground wire  .
|
|
|
03-31-2009, 04:40 PM
|
#10
|
|
Member
Join Date: Jan 2008
Posts: 71
|
I've seen a lot but that's the worst. There should be some kind of reward, like prison.
|
|
|
03-31-2009, 05:07 PM
|
#11
|
|
Senior Member
Join Date: Oct 2008
Location: michigan
Posts: 209
|
It doesn't look like the disconnect is secured to the house. Where does the ground connect inside the meter? Nice mess!
|
|
|
03-31-2009, 05:12 PM
|
#12
|
|
Senior Member
Join Date: Jan 2008
Posts: 1,356
|
 this looks like everyday work for the man the myth the legend peter d himself
|
|
|
03-31-2009, 06:11 PM
|
#13
|
|
child please.....
Join Date: Oct 2008
Location: Hack City, USA aka New Orleans
Posts: 2,955
|
Quote:
Originally Posted by seo
It doesn't look like the disconnect is secured to the house. Where does the ground connect inside the meter? Nice mess!
|
yeah, i assume inside the meterpan...they have #6 connected to the water pipe
|
|
|
03-31-2009, 08:02 PM
|
#14
|
|
Senior Member
Join Date: Apr 2008
Location: Rhinelander Wisconsin
Posts: 153
|
Kens emoticon says it all. What a hack job. Did the HO do this??
|
|
|
03-31-2009, 08:15 PM
|
#15
|
|
child please.....
Join Date: Oct 2008
Location: Hack City, USA aka New Orleans
Posts: 2,955
|
no, i really don't know who did it...she hired a g.c. and he got 3 different "electricians" to wire it...then he got another "electrician" to build the service...
|
|
|
03-31-2009, 08:37 PM
|
#16
|
|
Senior Member
Join Date: Feb 2008
Location: Atlanta, Ga/Hamilton, Al
Posts: 2,035
|
Quote:
Originally Posted by NolaTigaBait
no, i really don't know who did it...she hired a g.c. and he got 3 different "electricians" to wire it...then he got another "electrician" to build the service...
|
Is there alot of this junk there? Need any help?
|
|
|
03-31-2009, 09:11 PM
|
#17
|
|
Senior Member
Join Date: Mar 2009
Location: Ottawa
Posts: 343
|
Quote:
Originally Posted by NolaTigaBait
The e.c. should go to jail along with the general contractor...i'm the 3rd electrician to be on this job...i think she hired little mexico electric to build the service....this poor lady is stuck in the middle of all of this, she almost started crying when the inspector and I were explaining all of the violations to her...i feel horrible, but it needs to be fixed
|
It sure as hell isn't fun telling someone they've been completely screwed over. I've never really run into it since I got into electrical, but when I was still working with my old man as a general contractor, we'd get a couple of those a year. Electrical is pretty well regulated here, but to be a general contractor, any idiot can go out and buy a couple tools, a pickup truck and BLAMMO he's on the job. Big part of the reason I got out of that rat race.
|
|
|
03-31-2009, 09:36 PM
|
#18
|
|
child please.....
Join Date: Oct 2008
Location: Hack City, USA aka New Orleans
Posts: 2,955
|
Quote:
Originally Posted by InPhase277
Is there alot of this junk there? Need any help? 
|
from what the inspector is telling me, yes!...he is running into alot of these...he wasn't even impressed, he showed me a condo on st. charles that had 27 meters scattered throughout the building...new orleans is a hack city
|
|
|
03-31-2009, 10:25 PM
|
#19
|
|
Senior Moment
Join Date: Dec 2007
Location: Amite, LA
Posts: 456
|
Quote:
Originally Posted by NolaTigaBait
from what the inspector is telling me, yes!...he is running into alot of these...he wasn't even impressed, he showed me a condo on st. charles that had 27 meters scattered throughout the building...new orleans is a hack city
|
Hey brother are these issues coming to light because of failures or are HO going to the building department because of the hack looking work?
|
|
|
03-31-2009, 11:23 PM
|
#20
|
|
Apprentice
Join Date: Apr 2008
Location: New Orleans, Louisiana
Posts: 1,201
|
Funny you mention the mexicans. I was out in Gentilly drillin' the channels in the ceiling joists today, running power from the generator so it was loud.
So I finish up a hole, step off the ladder and turn around and "HOLY ****!".
'Lil Mexican Mario was standing there.
In broken english he was asking if we had work because his work was slow.
I looked outside and saw a ****ty ass van with no decals, but he did have a company shirt on.
Told him we didn't, though.
Hey Tigabait, if you need some help, I'd lend ya a hand.
I'd only be available during the weekends, though.
|
|
|
| Thread Tools |
Search this Thread |
|
|
|
| Display Modes |
Linear Mode
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
Similar Threads
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
|
Fun Pics
|
PhatElvis |
Residential Electrical Forum |
24 |
12-12-2009 02:45 PM |
|
Unlicensed hack
|
Minuteman |
Off Topic |
7 |
03-31-2009 09:51 AM |
|
Hack Heaven
|
NolaTigaBait |
General Electrical Discussion |
11 |
03-31-2009 09:05 AM |
|
Pics of your Service Van
|
elecapp79 |
General Electrical Discussion |
32 |
11-22-2008 12:38 PM |
|
new pics
|
calimurray |
General Electrical Discussion |
4 |
06-08-2008 09:04 PM |
|
|