Old 10-22-2015, 01:11 PM   #1
Junior Member
 
Join Date: Oct 2015
Location: Pacific Northwest
Posts: 5
Rewards Points: 10
Default Neutral - Blue, or LIGHT blue

As I search through the internet, I find some sites that say the EU wiring uses light blue for neutral, but other sites just say blue. Which is it? How critical is this?

I kinda need to know because I am having NO luck finding a distributor that carries 6awg light blue UL-MTW wire.
Feyd313 is offline   Reply With Quote
Join Contractor Talk

Join the #1 Electrician Forum Today - It's Totally Free!

ElectricianTalk.com - Are you a Professional Electrical Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for electricians to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that ElectricianTalk.com is a great community to join. Best of all it's totally free!

Join ElectricianTalk.com - Click Here JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ElectricianTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Sponsored Links
Advertisement
 
Old 10-22-2015, 01:20 PM   #2
Senior Member
 
Join Date: Jan 2011
Location: canada
Posts: 1,214
Rewards Points: 1,542
Default

in eu power cord it is often regular blue
oliquir is offline   Reply With Quote
Old 10-22-2015, 01:21 PM   #3
RIP 1959-2015
 
Black Dog's Avatar
 
Join Date: Oct 2011
Location: Reporting From Fenway Park Home of the Boston Red Sox....
Posts: 10,726
Rewards Points: 180
Default

Quote:
Originally Posted by Feyd313 View Post
As I search through the internet, I find some sites that say the EU wiring uses light blue for neutral, but other sites just say blue. Which is it? How critical is this?

I kinda need to know because I am having NO luck finding a distributor that carries 6awg light blue UL-MTW wire.
We cannot use blue light or otherwise as a neutral, are you working in the UK?

Welcome to the forum
__________________


CS2 Flat Rate
Black Dog is offline   Reply With Quote
Old 10-22-2015, 01:29 PM   #4
Moderator

 
Dennis Alwon's Avatar
 
Join Date: May 2009
Location: Chapel Hill, NC
Posts: 19,416
Rewards Points: 558
Default

Quote:
Originally Posted by Black Dog View Post
We cannot use blue light or otherwise as a neutral, are you working in the UK?

Welcome to the forum
No we can't but often I get listed fixtures that have a blue neutral. Some equipment also comes with blue wiring for the neutral. We cannot use blue in out field wiring but we can connect to it in listed products
Dennis Alwon is online now   Reply With Quote
Old 10-22-2015, 01:54 PM   #5
Junior Member
 
Join Date: Oct 2015
Location: Pacific Northwest
Posts: 5
Rewards Points: 10
Default

This is for wiring of equipment that the customer wants to be wired "globally". This is why it has to meet UL-508 standard, AND has to be CE certified.
Feyd313 is offline   Reply With Quote
Old 10-22-2015, 02:01 PM   #6
Junior Member
 
Join Date: Oct 2015
Location: Pacific Northwest
Posts: 5
Rewards Points: 10
Default

Here's a reference I came across:

http://www.openelectrical.org/wiki/i...le_Colour_Code
Feyd313 is offline   Reply With Quote
Old 10-22-2015, 03:42 PM   #7
RIP 1959-2015
 
Black Dog's Avatar
 
Join Date: Oct 2011
Location: Reporting From Fenway Park Home of the Boston Red Sox....
Posts: 10,726
Rewards Points: 180
Default

Quote:
Originally Posted by Feyd313 View Post
That's cool, in Switzerland line 3 is white..
__________________


CS2 Flat Rate
Black Dog is offline   Reply With Quote
Old 10-22-2015, 03:55 PM   #8
Senior Member
 
just the cowboy's Avatar
 
Join Date: Sep 2013
Location: Pa
Posts: 832
Rewards Points: 194
Default Just got a machine in from Germany

We just got a new machine in from Germany and this is what they used.
Machine is feed with 380/230v 3 phase with 120v single ulitily rectp.

Blue - DC hot
Blue/wh stripe - DC minus
Black - line voltage
Red - 120 volt hot
Light blue - Neutral for 230volt
White - neutral for 120 volt
Orange - interconnecting machine wires
Yellow - Hot wires not disconnected by main switch ( panel AC and lights)
Green/yel stripe - ground
__________________
A cowboy may get thrown down, but he always gets up and walks forward and don't look back at what thru him.
just the cowboy is online now   Reply With Quote
Old 10-23-2015, 08:45 AM   #9
Very Long Vacation
 
Join Date: Jan 2011
Location: united states of america
Posts: 11,719
Rewards Points: 5,262
Default

Quote:
Originally Posted by Feyd313 View Post

Its dated, Black is no longer used as a neutral in the UK, same for blue being used as as a phase.
Essex likes this.
meadow is offline   Reply With Quote
Old 10-23-2015, 08:49 AM   #10
Very Long Vacation
 
Join Date: Jan 2011
Location: united states of america
Posts: 11,719
Rewards Points: 5,262
Default

Here is the current colot code requirement for most countries based on IEC 60446:
Attached Thumbnails
Neutral - Blue, or LIGHT blue-color-1.jpg  

Neutral - Blue, or LIGHT blue-color-2.jpg  

meadow is offline   Reply With Quote
Old 10-23-2015, 08:52 AM   #11
Very Long Vacation
 
Join Date: Jan 2011
Location: united states of america
Posts: 11,719
Rewards Points: 5,262
Default

Quote:
Originally Posted by Black Dog View Post
That's cool, in Switzerland line 3 is white..

Neutral used to be black in the UK
Attached Thumbnails
Neutral - Blue, or LIGHT blue-3phasecolours.jpg  

Neutral - Blue, or LIGHT blue-2009121801e.jpg  

Essex likes this.

Last edited by meadow; 10-23-2015 at 08:56 AM.
meadow is offline   Reply With Quote
The Following User Says Thank You to meadow For This Useful Post:
Feyd313 (10-23-2015)
Old 10-23-2015, 09:36 PM   #12
Senior Member
 
Join Date: Aug 2013
Location: NL, Canada
Posts: 1,087
Rewards Points: 2,755
Default

Quote:
Originally Posted by just the cowboy View Post
We just got a new machine in from Germany and this is what they used.
Machine is feed with 380/230v 3 phase with 120v single ulitily rectp.

Blue - DC hot
Blue/wh stripe - DC minus
Black - line voltage
Red - 120 volt hot
Light blue - Neutral for 230volt
White - neutral for 120 volt
Orange - interconnecting machine wires
Yellow - Hot wires not disconnected by main switch ( panel AC and lights)
Green/yel stripe - ground
Looks like they have wired for the north american market. That color code is very similar to what we use a lot for automotive manufacturing lines, except we use white (or white with black or red strip) for all the neutrals.
AK_sparky is online now   Reply With Quote
Old 11-11-2015, 10:28 PM   #13
Member
 
Tony S's Avatar
 
Join Date: Jan 2014
Location: Resting under the Major Oak
Posts: 41
Rewards Points: 82
Default

Light blue often denotes DC neutral. Not that many panel manufactures seem to take any notice.

Bring back Red, White, Blue and Black. White was replaced in the late 70’s with Yellow, just in time to confuse a young wet behind the ears apprentice starting out in the trade.

The new harmonised colours are a disaster in the making. In low light……… I’ll let you decide.
__________________
Iím English so what do I know?

Last edited by Tony S; 11-11-2015 at 10:31 PM.
Tony S is offline   Reply With Quote
The Following User Says Thank You to Tony S For This Useful Post:
Old 11-20-2015, 07:53 PM   #14
Very Long Vacation
 
Join Date: Jan 2011
Location: united states of america
Posts: 11,719
Rewards Points: 5,262
Default

Quote:
Originally Posted by Tony S View Post
Light blue often denotes DC neutral. Not that many panel manufactures seem to take any notice.

Bring back Red, White, Blue and Black. White was replaced in the late 70ís with Yellow, just in time to confuse a young wet behind the ears apprentice starting out in the trade.

The new harmonised colours are a disaster in the making. In low lightÖÖÖ Iíll let you decide.


Did this color scheme come out of Geneva Switzerland? Im all for the old colors.
meadow is offline   Reply With Quote
The Following User Says Thank You to meadow For This Useful Post:
Tony S (11-21-2015)
Old 11-20-2015, 08:13 PM   #15
Senior Member
 
Join Date: May 2015
Location: Sacramento, California
Posts: 8,750
Rewards Points: 15,776
Default

Quote:
Originally Posted by AcidTrip View Post


Did this color scheme come out of Geneva Switzerland? Im all for the old colors.
I'm afraid you missed it: the committee decided to make EVERYONE unhappy.

That levelled the playing field.

That's how collective decisions get made.
telsa is online now   Reply With Quote
Old 11-21-2015, 12:44 AM   #16
Member
 
Tony S's Avatar
 
Join Date: Jan 2014
Location: Resting under the Major Oak
Posts: 41
Rewards Points: 82
Default

Quote:
Originally Posted by AcidTrip View Post


Did this color scheme come out of Geneva Switzerland? Im all for the old colors.
Brussels!

Belgium canít even get their voltage inline with the rest of Europe.
__________________
Iím English so what do I know?
Tony S is offline   Reply With Quote
Old 11-21-2015, 01:49 AM   #17
Very Long Vacation
 
Join Date: Jan 2011
Location: united states of america
Posts: 11,719
Rewards Points: 5,262
Default

Quote:
Originally Posted by Tony S View Post
Brussels!

Belgium canít even get their voltage inline with the rest of Europe.

What was so special about that color code?
meadow is offline   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
For Sale: Hazardous location J Boxs + More Blue Light Special! Introyble Electrician Swap 1 06-27-2013 08:24 PM
Go blue!!!!!!! ElectricZombie Off Topic (Non Trade) 6 05-07-2013 09:03 PM
The Blue Book, Once again. BobsELC Business, Marketing, and Sales 4 02-04-2012 01:02 PM
The Blue Book sparkie2010 Business, Marketing, and Sales 13 01-20-2012 12:24 AM
blue book? sparky=t Business, Marketing, and Sales 1 09-14-2011 11:04 AM


All times are GMT -4. The time now is 01:08 PM.


Powered by vBulletin® Version 3.8.8
Copyright ©2000 - 2017, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.1
vBulletin Security provided by vBSecurity v2.2.2 (Pro) - vBulletin Mods & Addons Copyright © 2017 DragonByte Technologies Ltd.
User Alert System provided by Advanced User Tagging (Pro) - vBulletin Mods & Addons Copyright © 2017 DragonByte Technologies Ltd.
Our Pro Sites Network
ContractorTalk.com | DrywallTalk.com | HVACSite.com | PaintTalk.com | PlumbingZone.com | RoofingTalk.com