Old 04-24-2007, 08:39 AM   #1
Senior Member
 
brian john's Avatar
 
Join Date: Mar 2007
Location: Leesburg VA
Posts: 6,529
Default Termination Conductor Spacing

If you look at this picture the mounting location of the neutral/grounded conductor was relocated. The neutral conductors have sufficient length to utilize the original location.

This 30 + year old building was currently remodeled, and it appears this transformer was relocated.


brian john is offline   Reply With Quote
Join Contractor Talk

Join the #1 Electrician Forum Today - It's Totally Free!

ElectricianTalk.com - Are you a Professional Electrical Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for electricians to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that ElectricianTalk.com is a great community to join. Best of all it's totally free!

Join ElectricianTalk.com - Click Here JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ElectrcianTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
Old 04-24-2007, 04:40 PM   #2
Senior Member
 
Join Date: Jan 2007
Location: Michigan
Posts: 265
Default

The Lug they had on the truck did not match the hole layout

if they really had to scab it in, maybe some mastic could have been used for insurance!
faber307 is offline   Reply With Quote
Old 04-24-2007, 04:42 PM   #3
Moderator
 
Join Date: Jan 2007
Location: Beautiful Cumberland Valley, in PA
Posts: 6,876
Default

Especially between two primary legs. They'd have even had to scrub off the shellac for the new mounting location, when that was already done in the factory location. Strange.
MDShunk is offline   Reply With Quote
Old 04-24-2007, 05:03 PM   #4
Senior Member
 
JohnJ0906's Avatar
 
Join Date: Jan 2007
Location: Baltimore, MD, USA
Posts: 3,490
Default

I hope that isn't as close as it looks
__________________
John from Baltimore
"One day at a Time"
All responses based on the '08 NEC
It's not my fault, it's not my problem, I'm not your solution.
JohnJ0906 is offline   Reply With Quote
Old 04-25-2007, 02:10 AM   #5
"Euro" electrician
 
Join Date: Mar 2007
Location: NE Wi / Paris France{ In France for while }
Posts: 637
Default

I hope my eyes is not teasing me but did the netural lug have 4 cables going in there ?? i know there is 2 for secondary side but what the heck going on primary side look like one netural or two grounding wires there and i am not sure if they did bonded the cabent with netural or ground hard to say there.

Merci, Marc
frenchelectrican is offline   Reply With Quote
Old 04-25-2007, 09:43 AM   #6
DJFVT
 
John's Avatar
 
Join Date: Jan 2007
Location: VT
Posts: 1,017
Default

Quote:
Originally Posted by frenchelectrican View Post
I hope my eyes is not teasing me but did the netural lug have 4 cables going in there ?? i know there is 2 for secondary side but what the heck going on primary side look like one netural or two grounding wires there and i am not sure if they did bonded the cabent with netural or ground hard to say there.

Merci, Marc
I saw that too and was wondering about it. It is hard to tell what the other 2 wires are, but there are 4 wires on that terminal.
The neutral connection is way too close the other phase connections for my comfort.

Carry On!
John is offline   Reply With Quote
Reply

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Conduit spacing chart. MDShunk General Electrical Discussion 30 02-23-2009 02:10 AM
neutral conductor chollapete NEC Code Forum 4 06-20-2008 08:20 PM
conductor question THREEPHASE NEC Code Forum 4 05-05-2008 11:38 PM
MWBC & Receptacle termination questions... Mackie General Electrical Discussion 17 04-10-2008 10:41 PM
Using the correct termination methods helps! Joe Tedesco Code Violation Discussion 10 03-26-2007 09:39 PM