    OK, you have everything you need there. 2VA x 50,000 = 100,000 VA now multiply times 40% = 40,000. OK ?

    Next remainder @ 20% The remainder of VA required is 6,250. X 2VA = 12,500. 12,500 x 20% = 2500. Now add the the two and you have the right amount 40,000 + 2.500. = 42,500 VA required
    Understand ?
  2. Matt G
    04-13-2013 01:56 PM - permalink
    Matt G
    Ok, Yeah I had found the table..

    I know that for Sq Ft in a hospital they say to use 2 Volts-Amps
    I also found the Demand factor for a Hospital to be at 40% for the first 50,000 and 20% for everything over 50,000..

    It's from that point on I'm not sure what to do..
    Each room is 15x25 = 375' x 150 rooms = 56,250sq ft
  3. dronai
    04-13-2013 01:00 PM - permalink
    dronai
    There is a table that list the amount of ltg load required and should show the demand factor you have to use.
  4. dronai
    04-13-2013 12:58 PM - permalink
    dronai
    I have to call on a job right now, but will show you when I get sometime today.
  5. Matt G
    04-13-2013 12:48 PM - permalink
    Matt G
    Hey dronai,

    I have a question, I've been going through all of the thought up questions (i'm preparing for my Journeyman's test) and I was going to ask if you can show me how to answer this question you posted? I was at the correct chapters but I'm uncertain of how to calculate it...

    A hospital has 150 patent's rooms, each room measuring 15'x25'. What is the lighting load (after demand factors) for these rooms ?
  6. John Valdes
    04-05-2013 08:46 PM - permalink
    John Valdes
    Dorian, Your inbox is full. I tried to send PM. About the thread block. Sorry........John
  7. ponyboy
    03-04-2013 09:39 PM - permalink
    ponyboy
    hey i tried to send you a pm and im not sure if it went or not. lemme know what you think!
  8. ponyboy
    02-16-2013 03:54 PM - permalink
    ponyboy
    your pm box is full
  9. Jlarson
    09-28-2012 10:36 PM - permalink
    Jlarson
    Your PM box is full.
  10. John Valdes
    11-02-2011 12:10 PM - permalink
    John Valdes
    Hello friend.

About Me

  • About dronai
    Biography
    26 yrs Resi/Comm, New Const Remod, Service , Industrial Automation App
    What is your electrical related field/trade:
    Electrical Contractor since 1989
    Location
    California
    Interests
    Music, learning PLC programming
    Occupation
    Service Electrician
  • My Company
    Company Name
    LNE
    Service Area
    Orange County, Ca.

Statistics

Total Posts
Visitor Messages
Total Thanks
General Information
  • Last Activity: Yesterday 07:52 PM
  • Join Date: 04-11-2011

Friends

Showing Friends 11 to 20 of 30
Top of Page | View New Posts

All times are GMT -4. The time now is 02:03 AM.


Electrician Talk © 2006 - 2010 The Building Network

Search Engine Optimization by vBSEO 3.6.0 RC 2