    I have a challenge at a new Dollar Plus store in Chicago: Cannot get power from breaker box [480V 600amp service], to leads outside 15' up, for the parking lot lights. Have live breakers at service panel inside for outside lights; sign (display) on both north and west wall work fine. They have their own switch box next to each of them. However, the conduits (poles) leading out, for the parking lot lights also 15' up, with two leads coming out of each of 10 separate holes 15' up along the west and south walls, have no power. Went back to double-check the breakers - 8, 10, 12, 14, and 16; designated for the outside lights [not the sign lights], and they are hot, with 20amp breakers. The relay switch for the signs (in a separate smaller service box next to the service panel) is operating just fine. So, what could be the problem; why can't I get power (LOAD) from the service panel inside, up to the wires outside, for the parking lot lights?

About Me

  • About Semi-Ret Electrician
    Professional Biography
    Bought my first codebook in 1958, been at it ever since
    What is your electrical related field/trade:
    Electrical Contractor, instrumentation designer, instructor
    General Location
    Birmingham, Alabama
    Special Skills, Interests, and Hobbies
    photography, SCUBA, boating, horses
    Occupation
    Electrical Contractor
  • My Company
    Company Name
    The Semi-Retired Electrician
    Service Area
    Shelby County, Alabama
  • Signature
    http://thesemi-retiredelectrician.com

Statistics

Total Posts
Visitor Messages
Total Thanks
General Information
  • Last Activity: Today 12:05 PM
  • Join Date: 11-09-2011
  • Referrals: 0

Friends

Showing Friends 1 to 10 of 23

Mentions

No results to display...

Quotes

02-19-2017
01:28 PM - Semi-Ret Electrician quoted ElectricalArtist in post Grounded systems
I get ur point ,but it's killing me l...
01:24 PM - Semi-Ret Electrician quoted varmit in post Grounding conductor from meter can
Grounding has more variable...
01:14 PM - Semi-Ret Electrician quoted ElectricalArtist in post Grounded systems
I think it's the flow of electric th...
02-18-2017
02:50 PM - Semi-Ret Electrician quoted 99cents in post Junk Halo 4" LED retrofit trims
He's an ultra-Liberal Americ...
02:49 PM - HackWork quoted Semi-Ret Electrician in post Poll: Tandem Breakers
I asked an inspector if tandems or 1/2 sp...
02-12-2017
02:51 PM - Semi-Ret Electrician quoted Flyingsod in post Why are threads on rigid conduit tapered?
I think the point micromind is...
02-11-2017
12:45 AM - Flyingsod quoted Semi-Ret Electrician in post Why are threads on rigid conduit tapered?
On a typical conduit to coupling connecti...
02-10-2017
11:25 PM - Semi-Ret Electrician quoted micromind in post Why are threads on rigid conduit tapered?
A tapered coupling would likel...
11:08 PM - micromind quoted Semi-Ret Electrician in post Why are threads on rigid conduit tapered?
I've been asking myself the same questio...
10:29 PM - MechanicalDVR quoted Semi-Ret Electrician in post Why are threads on rigid conduit tapered?
I've been asking myself the same questio...
06:52 PM - Semi-Ret Electrician quoted MechanicalDVR in post electrician? or linemen?
This is something I was just watch...
02-09-2017
01:32 PM - Semi-Ret Electrician quoted sbrn33 in post Copper prices
Did he share? I normally ta...
02-07-2017
05:42 PM - Flyingsod quoted Semi-Ret Electrician in post Copper prices
True, it's much easier to make prediction...
04:06 PM - Semi-Ret Electrician quoted PlugsAndLights in post Copper prices
Itís Difficult to Make Predictions,...
03:59 PM - Semi-Ret Electrician quoted John Valdes in post Personable personalities
In this case something should ha...
02-06-2017
02:58 PM - John Valdes quoted Semi-Ret Electrician in post Personable personalities
I worked for an EC who was totally rolled...
02-03-2017
05:22 PM - Majewski quoted Semi-Ret Electrician in post WTF is it About Residential Contractors
When I meet a client and all they can tal...
02-01-2017
08:23 PM - emtnut quoted Semi-Ret Electrician in post Separate grounds, fix on older homes.
What column on 310.15 (B) (16) does one u...
08:22 PM - emtnut quoted Semi-Ret Electrician in post Separate grounds, fix on older homes.
Sbrn33 may have experienced a shock on th...
06:29 PM - Semi-Ret Electrician quoted RePhase277 in post Separate grounds, fix on older homes.
This has been done to death acr...

All times are GMT -4. The time now is 01:25 PM.


Powered by vBulletin® Version 3.8.8
Copyright ©2000 - 2017, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.1
vBulletin Security provided by vBSecurity v2.2.2 (Pro) - vBulletin Mods & Addons Copyright © 2017 DragonByte Technologies Ltd.
User Alert System provided by Advanced User Tagging (Pro) - vBulletin Mods & Addons Copyright © 2017 DragonByte Technologies Ltd.
Our Pro Sites Network
ContractorTalk.com | DrywallTalk.com | HVACSite.com | PaintTalk.com | PlumbingZone.com | RoofingTalk.com