Reply
 
Thread Tools Display Modes
Old 05-25-2020, 08:39 PM   #1
Junior Member
 
Join Date: Feb 2020
Posts: 16
Rewards Points: 26
Default Supporting MC?

Inspector said I have to support mc in an accessible ceiling 12" from a light fixture. I cited 330.30(D)(2). Any thoughts?
Steven A. is offline   Reply With Quote
Join Contractor Talk

Join the #1 Electrician Forum Today - It's Totally Free!

ElectricianTalk.com - Are you a Professional Electrical Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for electricians to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that ElectricianTalk.com is a great community to join. Best of all it's totally free!

Join ElectricianTalk.com - Click Here JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ElectricianTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Sponsored Links
Advertisement
 
Old 05-25-2020, 10:25 PM   #2
Beam Me Up Scotty
 
Kevin_Essiambre's Avatar
 
Join Date: Feb 2017
Location: Ottawa, Ontario, Canada
Posts: 2,132
Rewards Points: 492
Default

I'd ask your journeyman... but let me guess, this is a side job?
The_Modifier and joebanana like this.
__________________
Vote Kevin for Moderator!
To view links or images in signatures your post count must be 10 or greater. You currently have 0 posts.
Kevin_Essiambre is online now   Reply With Quote
Old 05-25-2020, 10:52 PM   #3
Senior Member
 
Join Date: Dec 2010
Location: So.Cal.
Posts: 4,145
Rewards Points: 8,233
Default

Since local codes can vary from area to area, it would help to know your area of operation. Los Angeles codes are different from almost any area in the US. (Seismic, and Title 24 being the main differences).
What does your spec. sheet say?
splatz likes this.
__________________
-------------------------------
~ She thinks I'm crazy, but I'm just growing old~
joebanana is offline   Reply With Quote
Sponsored Links
Advertisement
 
Old 05-26-2020, 08:56 AM   #4
Electron Pathway Engineer
 
The_Modifier's Avatar
 
Join Date: Oct 2009
Location: On cloud 9 in Ontario
Posts: 2,992
Rewards Points: 760
Default

Quote:
Originally Posted by Steven A. View Post
Any thoughts?
Yup, plenty of them- first one that comes to mind- can you read?

For example- filling out your profile

AS PER THE USER SIGN UP AGREEMENT

Specifically your electrically related field

Your apprenticeship level.

The province that you live in for us to cite the codes that may be local to you.

99cents and Kevin_Essiambre like this.
__________________
Opportunities multiply as they are seized.
The_Modifier is offline   Reply With Quote
Old 05-26-2020, 09:15 AM   #5
Petulant Amateur
 
99cents's Avatar
 
Join Date: Aug 2012
Location: Perky Nipples, Canada
Posts: 23,941
Rewards Points: 3,311
Default

Maybe we should combine this thread with one of your other threads. Your favorite tool should be a tape measure so you can measure 12” from a box.
99cents is online now   Reply With Quote
Old 05-26-2020, 09:18 AM   #6
Petulant Amateur
 
99cents's Avatar
 
Join Date: Aug 2012
Location: Perky Nipples, Canada
Posts: 23,941
Rewards Points: 3,311
Default

Quote:
Originally Posted by The_Modifier View Post
Yup, plenty of them- first one that comes to mind- can you read?

For example- filling out your profile

AS PER THE USER SIGN UP AGREEMENT

Specifically your electrically related field

Your apprenticeship level.

The province that you live in for us to cite the codes that may be local to you.

He’s American. He is using a measurement derived from the anatomy of an ancient monarch.
The_Modifier likes this.
99cents is online now   Reply With Quote
Old 05-26-2020, 09:19 AM   #7
Gold Pliers Champion
 
Signal1's Avatar
 
Join Date: Feb 2016
Location: Boston Area
Posts: 2,574
Rewards Points: 2,720
Default

You're citing the correct code article, good on you.

Like Joe said, depending on your area, there might be something local the inspector is dinging you on.
splatz likes this.
__________________
"Hanging ceiling fans for grandma"


M E T G A !
Signal1 is offline   Reply With Quote
Old 05-26-2020, 11:50 AM   #8
Senile Member
 
macmikeman's Avatar
 
Join Date: Jan 2007
Location: Honolulu
Posts: 30,139
Rewards Points: 22,691
Default

I just loves me some mc cable. There's my support.
splatz and TheLivingBubba like this.
__________________
"Can you just imagine how much better the U.S.A. could have been without all the impeachment, Russia, attempted coup falsehood crap?".......ALARMGUY
macmikeman is online now   Reply With Quote
Old 05-26-2020, 04:28 PM   #9
Senior Member
 
VELOCI3's Avatar
 
Join Date: Aug 2019
Location: NY
Posts: 727
Rewards Points: 118
Default

3’ if it’s lights in a drop ceiling


Sent from my iPhone using Tapatalk
VELOCI3 is offline   Reply With Quote
Old 05-26-2020, 04:35 PM   #10
Senior Member
 
Join Date: May 2015
Location: Sacramento, California
Posts: 14,383
Rewards Points: 27,012
Default

Veloci3 -- you should've cited 330.30(D)(2) -- an accessible ceiling is a drop ceiling.

You can buy listed MC/ AC whips that are exactly 6' -- sold by the drum, BTW.
macmikeman likes this.
telsa is offline   Reply With Quote
Old 05-26-2020, 04:52 PM   #11
Gold Pliers Champion
 
Signal1's Avatar
 
Join Date: Feb 2016
Location: Boston Area
Posts: 2,574
Rewards Points: 2,720
Default

Quote:
Originally Posted by VELOCI3 View Post
3’ if it’s lights in a drop ceiling


Sent from my iPhone using Tapatalk
I think in the OP's example, D2 applies
__________________
"Hanging ceiling fans for grandma"


M E T G A !
Signal1 is offline   Reply With Quote
Old 05-26-2020, 05:28 PM   #12
Senile Member
 
macmikeman's Avatar
 
Join Date: Jan 2007
Location: Honolulu
Posts: 30,139
Rewards Points: 22,691
Default

Rightly divide the code! 2nd Timothy, verse : I forgots . ...................
__________________
"Can you just imagine how much better the U.S.A. could have been without all the impeachment, Russia, attempted coup falsehood crap?".......ALARMGUY
macmikeman is online now   Reply With Quote
Old 05-26-2020, 05:37 PM   #13
Registered Member
 
Join Date: Jan 2019
Location: SC
Posts: 4,676
Rewards Points: 554
Default

I support MC all the way! You can do it, MC!
RRF likes this.
CoolWill is offline   Reply With Quote
Old 05-26-2020, 06:29 PM   #14
Senior Member
 
Join Date: Oct 2012
Location: US
Posts: 3,436
Rewards Points: 1,910
Default

Quote:
Originally Posted by Steven A. View Post
Inspector said I have to support mc in an accessible ceiling 12" from a light fixture. I cited 330.30(D)(2). Any thoughts?
We had to do this once because my superintendent pissed off the inspector with a [email protected] comment.


MC really shouldn't be secured within 12'' of a light fixture, it makes maintenance a pain, and if the MC isn't run just right, you need to bend it pretty tight to secure it.
TGGT is offline   Reply With Quote
Old 07-11-2020, 03:50 PM   #15
Senior Member
 
Easy's Avatar
 
Join Date: Oct 2017
Location: Southern California
Posts: 986
Rewards Points: 1,988
Default

MC needs to be supported within 3 feet of a fixture as stated in the NEC. There is only one small catch. You can't support from any ceiling wires that supports the t-bar ceiling so you need to put in your own drop wires. Here is a adjustable lag pole that goes to 23 feet and if you stand on top of an 8 ft ladder and your 6'7" tall you can really get up there. This tool also works for 1/4" and 3/8" drop rod.
tmessner and splatz like this.

Last edited by Easy; 07-11-2020 at 04:01 PM.
Easy is offline   Reply With Quote
Old 07-11-2020, 04:43 PM   #16
Trained Monkey
 
TheLivingBubba's Avatar
 
Join Date: Jul 2015
Location: Isolation
Posts: 943
Rewards Points: 1,632
Default

https://www.erico.com/category.asp?category=R1315


Take your pick. Throw a few of those around and make it look neat.
Attached Thumbnails
Supporting MC?-ph6000m.jpg  
__________________
Make America Great Again...I want an Arby's in every city!
TheLivingBubba is offline   Reply With Quote
Old 07-11-2020, 06:46 PM   #17
Senior Member
 
Join Date: Dec 2010
Location: So.Cal.
Posts: 4,145
Rewards Points: 8,233
Default

Quote:
Originally Posted by Easy View Post
MC needs to be supported within 3 feet of a fixture as stated in the NEC. There is only one small catch. You can't support from any ceiling wires that supports the t-bar ceiling so you need to put in your own drop wires. Here is a adjustable lag pole that goes to 23 feet and if you stand on top of an 8 ft ladder and your 6'7" tall you can really get up there. This tool also works for 1/4" and 3/8" drop rod.
Ah, the ol' quake pole. I wonder what they call them outside Cali.
__________________
-------------------------------
~ She thinks I'm crazy, but I'm just growing old~
joebanana is offline   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



All times are GMT -4. The time now is 02:42 AM.


Powered by vBulletin® Version 3.8.8
Copyright ©2000 - 2020, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.1
vBulletin Security provided by vBSecurity v2.2.2 (Pro) - vBulletin Mods & Addons Copyright © 2020 DragonByte Technologies Ltd.
User Alert System provided by Advanced User Tagging (Pro) - vBulletin Mods & Addons Copyright © 2020 DragonByte Technologies Ltd.
Our Pro Sites Network
ContractorTalk.com | DrywallTalk.com | HVACSite.com | PaintTalk.com | PlumbingZone.com | RoofingTalk.com