Old 07-18-2016, 06:23 AM   #21
Retired Account
 
Join Date: Mar 2011
Location: the Green Mountain state
Posts: 39,722
Rewards Points: 14,650
Default

Oh yeah, in fact we just run a load of 3/4" from a troffer on out ,and wait for appliances to arrive....~CS~
MechanicalDVR likes this.
chicken steve is offline   Reply With Quote
Join Contractor Talk

Join the #1 Electrician Forum Today - It's Totally Free!

ElectricianTalk.com - Are you a Professional Electrical Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for electricians to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that ElectricianTalk.com is a great community to join. Best of all it's totally free!

Join ElectricianTalk.com - Click Here JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ElectricianTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Sponsored Links
Advertisement
 
Old 07-18-2016, 11:06 AM   #22
Senile Member
 
macmikeman's Avatar
 
Join Date: Jan 2007
Location: Honolulu
Posts: 26,959
Rewards Points: 16,277
Default

Every restaurant I ever wired I just ran as many 3/4 hole and stub ups to the grid ceiling as I could fit onto the top of the panels after making allowance for any required 1'' pipes or larger if required. Those always got used up magically for some reason or another. Charge large for everything not on the prints. Make sure to put that into the contract- not showing it cost more period or you will get screwed every time. Nobody mentioned electrical boxes getting buried behind the marlite wall coverings in the kitchens yet- that makes it superbly difficult to locate them- instead of searching for a lump in the wall you are looking for soft spots in the paneling. To combat that I used to put 6-32 screws into all the boxes set in the wall right after the drywaller's were done, before the GC started installing the wall coverings, and learned how to take boatloads of pictures of my rough ins. Then there is the fast food places that had energy management systems that linked to the mainland office- those required lots of added contactors and control wiring not really laid out so well for you on the prints. I haven't done a restaurant in a long time, but I haven't purposely shot myself in the foot for a long time either.................
__________________
Thought for the Day: President Trump is the first sitting U.S. president to EVER step foot in North Korea... Obama got a Nobel Peace Prize for being black.
macmikeman is online now   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Looking for electrical wiring service antondiaz General Electrical Discussion 4 06-20-2016 03:57 PM
Wiring Motors (High or Low Voltage?) JasonCo General Electrical Discussion 17 05-18-2016 01:37 PM
Wiring devices for aluminum wiring. NitroTurkey Residential Electrical Forum 5 03-20-2016 06:36 PM
Wiring Left in Distribution Panel Hdinj Code Violation Discussion 26 02-07-2016 11:31 PM
NPLFA circuit wiring khfiei General Electrical Discussion 5 02-05-2016 11:03 PM


All times are GMT -4. The time now is 01:10 PM.


Powered by vBulletin® Version 3.8.8
Copyright ©2000 - 2019, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.1
vBulletin Security provided by vBSecurity v2.2.2 (Pro) - vBulletin Mods & Addons Copyright © 2019 DragonByte Technologies Ltd.
User Alert System provided by Advanced User Tagging (Pro) - vBulletin Mods & Addons Copyright © 2019 DragonByte Technologies Ltd.
Our Pro Sites Network
ContractorTalk.com | DrywallTalk.com | HVACSite.com | PaintTalk.com | PlumbingZone.com | RoofingTalk.com