    My understanding of the California law requiring an employer to offer a non-mandatory lunch break of 1/2 hr during a standard 8 hr. work shift is that our electricians do not have to take this lunch break and consequently are working a 7-1/2 day. Am I wrong to think this effects productivity by essentially not giving the electrician the "fuel or break" he/she may need to sustain a high and fast pace throughout the day? I catch the fact that those who opt to not take a lunch seem to "graze" from their lunch box throughout the day which I argue is slowing up production and essentially eats up at least a 1/2 hour because of multiple trips to the truck or gang box to grab a "quick snack" and eat while working. To me it's not as simple as demanding a uniformed rule to take a lunch break and assume all is well with that company policy. I've worked in the field enough amongst the Rank and File to know that this may cause problems with attitude, production, moral. Any thoughts?
  2. 2825mdh1
    12-02-2016 01:11 PM - permalink
    2825mdh1
    Customer wants us to install a UPS for his IT Rack and some work stations. I'm figuring a 30 KVA 3-phase 208 volt UPS with battery back up @ 3-5 hours. Can anyone tell me if there is anything more that i should be considering beyond intercepting the power source from the MSB/MCB to the electrical panel from which the IT Rack and work station circuits are fed and taking it to the UPS and then from the UPS to the panel? Besides grounding I can't think of anything else i should consider. Do the UPS systems typically come equipped with everything needed from the factory?
  3. 2825mdh1
    11-26-2016 04:20 PM - permalink
    2825mdh1
    Customer wants us to install a UPS for his IT Rack and some work stations. I'm figuring a 30KVA 3-phase 208 volt UPS with battery back up @ 3-5 hours and a external connection source to additional batteries to provide up to 8 hours of back up power. Can anyone tell me if there is anything more that I should consider beyond intercepting the source power from MSB/MCB to the electrical panel from which the IT Rack and workstations are fed via branch circuits and taking it to the UPS and then back out again? Do these UPS's generally come from the factory equipped with everything required to automatically transfer the loads when power loss detected?

About Me

  • About 2825mdh1
    What is your electrical related field/trade:
    Commercial Electrical Contractor
    General Location
    Concord, Ca.

Statistics

Total Posts
Visitor Messages
Total Thanks
General Information
  • Last Activity: 01-19-2017 04:28 PM
  • Join Date: 09-06-2016
  • Referrals: 0

Mentions

No results to display...

Quotes

12-04-2016
06:05 AM - Southeast Power quoted 2825mdh1 in post UPS Wiring
Besides intercepting a 100 am...
12-03-2016
06:13 PM - macmikeman quoted 2825mdh1 in post UPS Wiring
Besides intercepting a 100 am...
11-12-2016
08:46 PM - Southeast Power quoted 2825mdh1 in post UL listing of equipment
I recently posted a question ...
10-22-2016
03:48 PM - Flyingsod quoted 2825mdh1 in post Salt Water Environment
We are about to start a comme...
09-30-2016
10:54 AM - Brain John quoted 2825mdh1 in post Lugs / Termination temperatures
Thank you to everyone for you...
09-29-2016
04:39 PM - Brain John quoted 2825mdh1 in post Lugs / Termination temperatures
Thank you LuckyLuke. Wild Leg...
10:39 AM - wildleg quoted 2825mdh1 in post Lugs / Termination temperatures
While performing a Panel Main...
10:32 AM - LuckyLuke quoted 2825mdh1 in post Lugs / Termination temperatures
While performing a Panel Main...
09-27-2016
04:21 PM - telsa quoted 2825mdh1 in post Buck Boost Transformer
Can someone educate me on how...
12:12 PM - frenchelectrican quoted 2825mdh1 in post Buck Boost Transformer
Can someone educate me on how...
09-07-2016
06:14 PM - Brain John quoted 2825mdh1 in post Linear Lighting System Problem
Linear meaning type of light....

All times are GMT -4. The time now is 07:16 PM.


Powered by vBulletin® Version 3.8.8
Copyright ©2000 - 2019, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.1
vBulletin Security provided by vBSecurity v2.2.2 (Pro) - vBulletin Mods & Addons Copyright © 2019 DragonByte Technologies Ltd.
User Alert System provided by Advanced User Tagging (Pro) - vBulletin Mods & Addons Copyright © 2019 DragonByte Technologies Ltd.
Our Pro Sites Network
ContractorTalk.com | DrywallTalk.com | HVACSite.com | PaintTalk.com | PlumbingZone.com | RoofingTalk.com