Electrician Talk - Professional Electrical Contractors Forum - View Profile: Lone Crapshooter
CLICK HERE AND JOIN OUR COMMUNITY TODAY, IT'S FREE!
Go Back   Electrician Talk - Professional Electrical Contractors Forum > Members List


Lone Crapshooter Lone Crapshooter is offline

Senior Member

Visitor Messages

Showing Visitor Messages 1 to 3 of 3
  1. Lep
    08-19-2012 11:23 PM - permalink
    Lep
    I usually do better at the craps table with a full table of people, have fun watching all the people getting lucky rolls. Gotta watch out when the house changes the dice though.
  2. bmart
    12-30-2011 10:09 AM - permalink
    bmart
    Delta wye transformers that are paralled on the secondary side can cause problems. The secondary breaker of one of the transformers failed to open from reverse current; however the source breaker (12 KV) opened up due to a fault and now you have an unaffected grounded system which put 12 KV across 7.2 kv phase to ground transformers primary and the seondary voltages were elevated to a much higher voltage than 208V and caused TV sets to explode. Was a big lawsuit.

    bmart
  3. bmart
    12-30-2011 10:05 AM - permalink
    bmart
    Delta wye transformers that are paralled on the secondary side can cause problems. The secondary breaker of one of the transformers failed to open from reverse current; however the source breaker (12 KV) opened up due to a fault and now you have an unaffected grounded system which put 12 KV across 7.2 kv phase to ground transformers primary and the seondary voltages were elevated to a much higher voltage than 208V and caused TV sets to explode. Was a big lawsuit.

    bmart

About Me

  • About Lone Crapshooter
    What is your electrical related field/trade:
    ELECTRICAL MERCENARY
    General Location
    east coast
  • Signature
    What tools do I need to carry? Use the NEC as your guide keep all your tools ACCESSABLE but keep your everyday tools READILY ACCESSABLE.

Statistics

Total Posts
Visitor Messages
Total Thanks
General Information
  • Last Activity: Today 06:16 AM
  • Join Date: 11-07-2008
  • Referrals: 1

Friends

Showing Friends 1 to 1 of 1

Mentions

07-03-2020
07:04 AM - splatz mentioned Lone Crapshooter in post Tying FM200 systems into SCADA 2.0
...ou were thinking of Lone Crapshooter ... If I follow yo...
04-09-2020
11:07 AM - splatz mentioned Lone Crapshooter in post Driving romex staples what is trade secrete ?
BTW, Lone Crapshooter, don't forget that y...

Quotes

06-21-2020
10:19 PM - splatz quoted Lone Crapshooter in post Old school build
I am looking at tying 5 FM200 extingu...
06-08-2020
06:17 PM - wcord quoted Lone Crapshooter in post Industrial work - tray cable
I am working on a mine tipple and it...
05-06-2020
08:53 PM - BKP quoted Lone Crapshooter in post Tke your time
To start with I do not like l residen...
04-18-2020
05:53 PM - wcord quoted Lone Crapshooter in post Homemade/Redneck tuggers
The contractors that worked for me ae...
04-12-2020
10:00 PM - macmikeman quoted Lone Crapshooter in post Driving romex staples what is trade secrete ?
I want to thank everyone for their in...
04-09-2020
10:40 PM - 220/221 quoted Lone Crapshooter in post Driving romex staples what is trade secrete ?
How complicated can it be to drive a ...
11:13 AM - Bird dog quoted Lone Crapshooter in post Driving romex staples what is trade secrete ?
To start with I do not like l residen...
10:28 AM - joe-nwt quoted Lone Crapshooter in post Driving romex staples what is trade secrete ?
To start with I do not like l residen...
10:00 AM - zac quoted Lone Crapshooter in post Driving romex staples what is trade secrete ?
Makes no difference pliers or hammer ...
09:55 AM - CoolWill quoted Lone Crapshooter in post Driving romex staples what is trade secrete ?
Makes no difference pliers or hammer ...
03-24-2020
04:44 AM - skyline77 quoted Lone Crapshooter in post Loooking for a IEEE standard in PDF
Thanks for your help. I was hoping ...
03-23-2020
10:35 AM - brian john quoted Lone Crapshooter in post Loooking for a IEEE standard in PDF
Thanks for your help. I was hoping ...
08:16 AM - skyline77 quoted Lone Crapshooter in post Loooking for a IEEE standard in PDF
I am looking for a old IEEE standard ...
03-19-2020
01:49 PM - macmikeman quoted Lone Crapshooter in post megger is always maxed out
If you have doubt that your Megger is...
03-11-2020
09:43 AM - splatz quoted Lone Crapshooter in post Everyone should have this anchor tool
I use DOUBLE MACHINE ANCHORS in hollo...
03-08-2020
11:14 AM - VELOCI3 quoted Lone Crapshooter in post Everyone should have this anchor tool
I use DOUBLE MACHINE ANCHORS in hollo...
01-07-2020
02:35 PM - flyboy quoted Lone Crapshooter in post Any tips on bending 500 and 700 Wiremold
We are using a Wiremold bender and be...
12-30-2019
12:10 PM - HackWork quoted Lone Crapshooter in post So I got a tick tester as a Xmas gift
The Santronics is on all of the time ...
10:39 AM - VELOCI3 quoted Lone Crapshooter in post So I got a tick tester as a Xmas gift
I have both Fluke and Santronics and ...
10:38 AM - five.five-six quoted Lone Crapshooter in post So I got a tick tester as a Xmas gift
I have both Fluke and Santronics and ...

All times are GMT -4. The time now is 10:16 AM.


Powered by vBulletin® Version 3.8.8
Copyright ©2000 - 2020, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.1
vBulletin Security provided by vBSecurity v2.2.2 (Pro) - vBulletin Mods & Addons Copyright © 2020 DragonByte Technologies Ltd.
User Alert System provided by Advanced User Tagging (Pro) - vBulletin Mods & Addons Copyright © 2020 DragonByte Technologies Ltd.
Our Pro Sites Network
ContractorTalk.com | DrywallTalk.com | HVACSite.com | PaintTalk.com | PlumbingZone.com | RoofingTalk.com