  1. Canadian Electrical Forum
    Question about house load calculations. We have been dividing a lot of houses into up/down suites with their own meters. If I can, I like to give the house a 400A service, but sometimes the customer does not want to pay for it if the existing loads fit under a 200A service. My question is, do...
  2. Canadian Electrical Forum
    Revised system: Need comments concerning compliance with the Canadian Electrical Code. Thank you.
  3. Commercial Electrical Forum
    So as per my last threads, I have been put in charge of a project I am not qualified for and rather than wait for instructions to be handed down or a mistake to appear later after things have been drywalled, I am taking the initiative to figure things out when something sounds wrong. So I am...
  4. Canadian Electrical Forum
    Hi, I have a 3Phase 1200Amp 120/208V Panel feeding a distribution panel 3phase 400Amp 120/208v. For the voltage in the Table D3 Calculation do I need to multiply by 1.73 for 3phase or just use 208/120? D x VD(%) x CF x (208/120x1.73)= Distance or D x VD(%) x CF x (208/120)= Distance...
  5. Fire Alarm Systems
    So I have been thrown in the deep end of figuring **** out and figured I'd ask around here. So we're using a Mircom Fx-2000 FA Panel, in a commercial office/residential combo 4 floor building. Top floor is apartments, 2nd and 3rd are offices, first is a lobby/parkade. The corridors are all...
  6. Commercial Electrical Forum
    I have recently been given WAY too much responsibility for the little skills I have and I feel incredibly out of my depths, so I am hoping you guys can help me out a little. I am new to reading nameplate data and I was wondering if you had any solid rules for when I need an extra circuit for a...
  7. Canadian Electrical Forum
    So I just did a job in a non sprinklered building. I had another more experienced foreman come help me and he said I need to change my connectors to rain tight since he just got called for it on his job. He says it’s because of the drip hood on the panel. I have the wire pulled and terminated...
  8. Canadian Electrical Forum
    22-302 Drainage, sealing, and exclusion of moisture 1) Where conduit is used, it shall be a) arranged to drain at frequent intervals to suitable locations; Δ b) equipped with fittings that permit the moisture to drain out of the system; What fittings and or methods do you guys use to comply...
  9. Canadian Electrical Forum
    What style of outlet is being used for 14-50 car charger outlets when located in a carport? Are people installing covers? The intended location is in a carport on the exterior wall of a residence which is attached to the carport. It is well away from any roof edges and will be at least 1 m...
  10. Canadian Electrical Forum
    Hi everyone, I know this may be a stretch but my dad’s asking me if I could ask to see if anyone knows if there’s a difference between grounding neutral gas generators and other generators in the CEC. And if there’s a difference between temporary and permanent installation? He’s been flipping...
  11. Canadian Electrical Forum
    Guys, this is killing me. Someone has to know the answer. Check out this drawing: 400A Service in, 125A feeder out to each panel w. 125A main breaker. I can Not figure out how this is allowed or the code rule that explains it. From what I see, we would be required to have protection at...
  12. Canadian Electrical Forum
    We are working in a smallish rack room trying to fit in a new cabinet. There are existing cabinets in the room, that have less than 1m working space. Was this rule added or changed from some smaller distance in the last 20-30 years when these older cabinets may have been installed?
    cec
  13. Canadian Electrical Forum
    According to the product page the Index has been deleted in conformance with CSA Group's drafting and editorial requirements. Oh, really.
  14. Canadian Electrical Forum
    Hi, I'm challenging the IP exam and I'll be writing here in BC on October 29th and just wondering if anyone who has written it lately(2018 code book) has any tips or specific things they remember? I've talked to a few friends who have wrote it in the past, they told me there is no math and just...
  15. Canadian Electrical Forum
    I have a 208v 3ph motor with a FLA of 5.9 which is plugged into a 20A locking receptacle. Is it is against code to put the circuits on a 3P 20A breaker?
  16. Canadian Electrical Forum
    I'm asking because I recently told my coworker that the conductor length was supposed to be the "width plus depth" of whatever box you are working with. But he asked for the code rule, and I told him it was something my teacher at school told me and made us implement countless times. He was a...
  17. General Electrical Discussion
    Is it possible for there to be no ground wire in an under ground PVC feeder conduit? Its 480v 3 wire. Doing demo and noticed this between two buildings in an industrial compound (all on one property). Is this an ungrounded or impedance grounded system? Please be gentle I have limited experience...
  18. Canadian Electrical Forum
    Is it possible for there to be no ground wire in an under ground PVC feeder conduit? Its 480v 3 wire. Doing demo and noticed this between two buildings in an industrial compound (all on one property). Is this an ungrounded or impedance grounded system? Please be gentle I have limited experience...
  19. Canadian Electrical Forum
    Hey guys, this is my first post and i a,m pretty exited about using this Forum. CEC Table 39 shows the size of conductors for residential service. CEC Table 5E, which is not printed in the CEC 2015 but in the STANDATA, seems to have the exact same info. Can someone help me clarify the...