feeders
1-9 of 9 Results
  1. General Electrical Discussion
    Hey everyone, first post here. I am a general contractor and am having some electrical work done on my personal property in rural Vermont. I was hoping to get any input on the electrical design as proposed (and initiated) by my electrician. My experience has been more in the suburbs, with single...
  2. Residential Electrical Forum
    Hi There: Happy Memorial Day to all. First post, about a post! Going to ditch witch trench 36 inches to accommodate 2.5" conduit, seventy feet, box at street to side of house. Two elbows/sweeps maximum. That puts it at footer, which stick out about a foot past outside wall. Panel mounted...
  3. General Electrical Discussion
    Hi all, I am brand new to the electrical field, and I am learning to write electrical estimates. I'm currently working on a 3 story commercial build, I have feeders run from transformer to electrical closet on first floor, as well as Emergency lines from the generator. I converted the conduit...
  4. General Electrical Discussion
    I am installing a meter base on a house that has 2 breakers feeding sub panels. One is a 200 amp breaker feeding a sub panel for the main house. The other is a 125 amp breaker feeding a DADU (detached mother in law). The DADU is going to have solar panels. The solar guys want at least a 150 amp...
  5. General Electrical Discussion
    i am working on a DADU (detached additional dwelling unit) in Seattle. I have to upgrade the main service at the house to 200 amps and put in a double socket meter base. The main house needs a 100 sub panel and the DADU also needs a 100 amp sub panel. Table 310.15b6 used to let me use #4 wire...
  6. General Electrical Discussion
    I looked at a condo today and all the branch circuit neutrals were burnt and corroded on the neutral bar in the condos panel. The feeder wires were 2/0 aluminum with a undersized neutral. I do not know the size of the neutral because the writing was worn off. My guess is that the feeder neutral...
  7. General Electrical Discussion
    Conclavicus raised that perennial issue: messed up ( crossed over ) paralleled conductors in a recent thread. So it's high time to post the magic solution that forever prevents this from ever happening to you. 1) Forget about phasing the parallel conductors during the pull. It's a total waste...
  8. General Electrical Discussion
    I am bidding on a couple of panel changes. - The first panel is fed from a 200A disconnect; the feeders are run in metal conduit with no equipment ground conductor. It seems to me that there might be an exception that allows this in an existing installation. (I want to leave the feeders alone in...
  9. Services and Service Equipment
    We just installed a brand new cutler hammer panelboard at work this week and when wiring it up we saw the feeds for the panel are the first three circuit breaker slots on the left side, which isn't abnormal around here. Now my question is, on the other side opposite the main breaker there is no...
1-9 of 9 Results